ECCN: EAR99
ECCN: EAR99
Output Unit
110g
ECCN: EAR99
CJ1WTC002
ECCN: EAR99
Controller
Memory backup battery for FX2N
CE(Battery)
Expansion block, extension cable for expansion unit
0.65m
Relay
Sink
Number of input points:4
Input connection shape: Vertical terminal block (M3 screw)
Number of output points:4
Output connection shape: Vertical terminal block (M3 screw)
Maximum load Resistive load: 2A/1 point
Input signal format: No-voltage contact input NPN or open collector transistor
Sink
Number of input points: 16
Input connection shape: Connector
Input signal current: 5mA/24VDC
2.2W
No-voltage contact input or NPN open collector transistor
Input signal voltage: 24V +20% -15% Ripple (p-p) within 5
Output connection shape: Connector
1.5V or less
Number of output points: 16
Maximum load Resistive load: 0.1A/1 point
0.35W
External power supply: 5 to 30VDC
Open circuit leakage current: 0.1mA or less/30VDC
0 point (not related to the maximum number of input/output points of the sequencer)
Analog output range: Voltage output: 0V to 10V DC (external load resistance 2kΩ to 1MΩ) Current output: 4mA to 20mA DC (external load resistance 500Ω or less)
Applicable sequencer: FX3S, FX3G (V1.10 or later) When FX3S is connected, the function expansion board and FX3S-CNV-ADP cannot be used together.
D/A conversion time: 60us (data is updated every operation cycle)
Isolation method: Non-isolation between analog input and sequencer, and between each channel
Number of output channels: 1 channel
0 point (not related to the maximum number of input/output points of the sequencer)
Analog input range: voltage input: 0V to 10V DC (input resistance 198.7kΩ) current input: 4mA to 20mA DC (input resistance 250Ω)
Applicable sequencer: FX3S, FX3G (V1.10 or later) When FX3S is connected, the function expansion board and FX3S-CNV-ADP cannot be used together.
A/D conversion time: 180 us (data is updated every operation cycle)
Isolation method: Non-isolation between analog input and sequencer, and between each channel
Number of input channels: 2 channels
Relay output
Sink/Source
50|60Hz
I/O control method: batch processing method (when END instruction is executed), I/O refresh instruction, pulse catch function
Programming language: Relay symbol method + step ladder method (SFC expression possible)
Number of input points:24
37W
Number of output points:16
Arithmetic control method: Stored program repetitive operation method, with interrupt instructions
Maximum memory capacity: 32000 steps 32000 steps including comment and file registers
100 to 240V
0 point (not related to the maximum number of input/output points of the sequencer)
Applicable sequencer: FX3S, FX3G When FX3S is connected, the function expansion board and FX3S-CNV-ADP cannot be used together.
Communication method: Half-duplex bidirectional
No procedure,Calculator link:300|600|1200|2400|4800|9600|19200|38400bps
RS-485,RS-422
Max 50m
External device connection method: European-type terminal block
Relay output
Sink/Source
50|60Hz
I/O control method: batch processing method (when END instruction is executed), I/O refresh instruction, pulse catch function
Programming language: Relay symbol method + step ladder method (SFC expression possible)
Number of input points:8
30W
Number of output points:8
Arithmetic control method: Stored program repetitive operation method (dedicated LSI), with interrupt function
Maximum memory capacity: 64000 steps including comments and file registers
100 to 240V
Memory backup battery for FX5U, FX5UC, FX3G, FX3U, FX3GC, FX3UC, IU2-3M10, IU2-1EMES-100M
Relay output
Sink/Source
50|60Hz
I/O control method: batch processing method (when END instruction is executed), I/O refresh instruction, pulse catch function
Programming language: Relay symbol method + step ladder method (SFC expression possible)
Number of input points:16
35W This is the value when the 24VDC service power supply of the basic unit is consumed at maximum by the additional input/output expansion block or special expansion unit/block.
Number of output points:16
Arithmetic control method: Stored program repetitive operation method (dedicated LSI), with interrupt function
Maximum memory capacity: 64000 steps including comments and file registers
100 to 240V
0 point (not related to the maximum number of input/output points of the sequencer)
Applicable sequencer: FX3U, FX3UC-32MT-LT(-2)
Communication method: Half-duplex bidirectional
5VDC 20mA (internally powered from sequencer)
9600|19200|38400|57600|115200bps
RS-422
MINI DIN 8pin(female)
0 point (not related to the maximum number of input/output points of the sequencer)
Applicable sequencer: FX3U, FX3UC-32MT-LT(-2)
Communication method: Half-duplex bidirectional
5VDC 40mA (internally powered from sequencer)
No procedure,Calculator link:300|600|1200|2400|4800|9600|19200|38400bps
Compliant with RS-485 and RS-422 standards
European Terminal Blocks